Heat transfer pumps




Field of application The volute pumps of the series are part of the overall programme heat transfer and circutation pumps. They are primarily used for circulation of hot water in closed pipe and vessel systems. Therefore their fields of application are the energy production, the heat transport industry and here mainly in systems where hot water as heat carrier is given preference, despite its high system pressure, over oil as heat carrier.
Description Horizontal, single-stage volute casing pumps with dimensions and nominal ratings to EN 22858 in back pull out design, with uncooled balanced mechanical seal. The series ZENhas especially been designed for the trouble free handling of hot water up to 230 °C. The back pull out design permits the removal of the complete bearing unit towards the drive end without removing the pump casing from the pipe work. If a spacer coupling is installed it is also unnecessary to disconnect the motor.

Technical data :


Flow rate: up to 600 m³/h
Head: up to 90 m
Speed: max. 3,600 rpm
Temperature: max. 230 °C
Casing pressure: up to 40 bar
Shaft seal: mechanical seal
Material: nodular iron, cast steel

 